Technical Data for the SIPLACE X-Series

 
Machine Features SIPLACE X4i S SIPLACE X4 S SIPLACE X3 S  SIPLACE X2 S
Number of gantries 4 4 3 2
Placement performance        
IPC Value 150,000 cph 150,000 cph 78,100 cph 52,000 cph
SIPLACE benchmark 150,000 cph 125,000 cph 94,500 cph 64,000 cph
Theoretical value 200,000 cph 170,500 cph 127,875 cph 85,250 cph
Machine Size         
  1.9 x 2.3 1 1.9 x 2.3 1 1.9 x 2.3 1 1,9 x 2,3 1
Placement Head
Features
SpeedStar    MultiStar      TwinStar
Component spectrum 0201 (metric) - 6 x 6 mm 03015 - 50 x 40 mm         0201" - 200 x 125 mm     
Placement accuracy  ± 41 μm/3σ ± 41 μm/3σ (C&P) ± 22 μm/3σ
    ± 34 μm/3σ (P&P)  
Angular accuracy  ± 0,5°/3σ ± 0,4°/3σ (C&P) ± 0,05°/3σ
    ± 0,2°/3σ (P&P)  
max. Component Height 4 mm 11,5 mm 25 mm
Placement Force 1,3 - 4,5 N 1,0 - 10 N 1,0 - 15 N 2
Conveyor Features        
Transport Types Single Transport, Flexible Dual Transport  
Transport Modes Asynchronous, synchronous, i-placement (X4i S)  
PCB format  50 x 50 mm to 650 x 560 mm max. (X4 S, X3 S, X2 S)  3
  50 x 50 mm to 610 x 560 mm max. (X4i S)
PCB thickness 0,3 to 4,5 mm (other thicknesses upon request)  
PCB weight 3 kg max.  
Component Supply and Feeding        
Feeder positions X3 S & X4 S: 160 tracks with 8 mm X-feeders
  X4i S: 148 tracks with 8 mm X-feeders
Component Supply  

SIPLACE component cart, SIPLACE Matrix Tray Changer (MTC) 4,
Wafflepack Changer (WPC5/WPC6) 4, JTF-S/JTF-M

  SIPLACE X-feeders

 

Tray, stick magazine, bulk case, application-specific OEM feeder modules

Quality Ratings        
Pickup rate ≥ 99,95% 5
DPM rate ≤ 3 dpm 6
Lighting levels up to 6
   
Performing professional maintenance in the scope and intervals recommended by ASM ensures that your SIPLACE equipment will deliver the specified performance and accuracy across its entire life cycle. Our various maintenance contracts make this job even easier for you.

1 Only for main body
2 maximum placement force 30 N possible with the Option SIPLACE HighForce Head
3 up tp 850 mm with Input- & Output Conveyor Extensions
4 only for SIPLACE X2 S, X3 S and X4 S - not for SIPLACE X4i S
5 Cannot be combined within the same placement area
6 According to evaluation criteria